HT-PD PR190 Technical data |
Overload range |
1.5 x nominal pressure |
Burst pressure |
3 x nominal pressure |
Signal type |
Two wire analog (4 ... 20 mA), three wire analog (0 ... 10 VDC) |
Supply voltage Ub |
... at 4 ... 20 mA |
10...30VDC |
... at 0 ... 10 VDC |
12...32VDC |
Current consumption |
6.5mA |
Overvoltage protection |
32VDC |
Error limit (of fi nal value) |
comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error |
... at +22 °C (room temperature) |
±0.5% |
... at -15 ... +85°C |
±1% |
... at +85 ... +100°C |
±2.5% |
... at -40 ... -15°C |
±2.5% |
Compensation temperature range |
-40...+100 |
Non-linearity |
< ± 0.4 % of final value |
Reproducability |
< ± 0.1 % of final value |
Hysterese |
< ± 0.1 % of final value |
Long-term stability |
< ± 0.1 % of final value/year |
Response time |
< = 1 ms (10 ... 90 %) |
Frequency range |
< = 1 kHz |
Isolation resistance |
min. 100 MOhm |
Total resistance |
RG = (Ub -10 V) / 20 mA (at output signal 4 ... 20 mA) |
Load resistance |
RL = > 5 kOhm (at output signal 0 ... 10 VDC) |
Number of load cycles |
> 1 x 107 |
Medium temperature |
-40...+125 |
Environmental temperature |
-40 ... +105 °C (short term +125 °C) |
Storage temperature |
-40...+125 |
EMV test |
EN 50081-2, EN 50082-2 |
Vibrational stability |
5 mm 10 ... 32 Hz, 20 g 32 ... 500 Hz, DIN EN 60068-2-6 |
Shock stability |
50 g (11 ms half-sine) |
Electrical measuring connector |
open ends, 4 wires, connection cable 1.5 m |
Mechanical connection thread |
ISO228-G1/4A |
Sealing material |
profi le seal ring acc. to DIN 3869, FKM |
Protection type (EN 60529 / IEC 529) |
IP 68 K |
Casing material |
non-corrosive high-grade steel |
Membrane material |
non-corrosive high-grade steel |
Tightening torque |
40 Nm (± 5 Nm) |
Weight |
~ 120 g |