Hydrotechnik panel mounted instruments SEG1060 Introduction
|
Panel mounted instruments SEG1060 |
Hydrotechnik |
SEG1060 data download |
The SEG 1060 is perfectly tuned to all Hydrotechnik sensors and guarantees reliable performance. Even under
diffi cult conditions, a problem-free integration is possible due to the small fi tting dimensions. The user-friendly
operation is done completely from the front panel of the device. |
Hydrotechnik panel mounted instruments SEG1060 Features
One analogue measuring input for 0 to 20 mA, 4 to 20 mA and 0 to 10 V |
Frequency input:0?0KHZ |
12 bit Analog/Digital-converter |
Measuring rate > 40 ms |
LED display, 4-digit, very good readability,even from greater distance |
Operation from the front panel |
Fitting dimensions 96 x 48 mm acc. to DIN 43718 |
Collection of min/max values |
Optional: limit value with potential-free change-over contact and analog output 0 to 10 Volt or 0 to 20 mA / 4 to 20 mA |
Switchboard cut-out 43 x 90,5 mm (H x W) |
Hydrotechnik panel mounted instruments SEG1060 Applications
Hydrotechnik SEG1060/SEG1050 order NO.
Supply voltage |
SEG1050 |
SEG1050 order NO. |
SEG1060 |
SEG1060 order NO. |
24VDC |
only display |
3192-03-02.00 |
only display |
3192-04-10.00 |
with option 1 analogue output |
3192-03-04.00 |
with option 1 analogue outpu |
— |
with option2 limit value |
3192-03-06.00 |
with option2 limit value |
— |
with option 1 analogue output and 2 limit value |
3192-03-08.00 |
with option 1 analogue output and 1 limit value |
3192-04-11.00 |
230VAC |
only display |
3192-03-01.00 |
only display |
3192-04-20.00 |
with option 1 analogue output |
3192-03-03.00 |
with option 1 analogue output |
— |
with option2 limit value |
3192-03-05.00 |
with option2 limit value |
— |
with option 1 analogue output and 2 limit value |
3192-03-07.00 |
with option 1 analogue output and 1 limit value |
3192-04-21.00 |
Hydrotechnik SEG1000 Order NO.
Supply voltage |
SEG1000 |
Analogue input |
Frequency input |
24VDC |
only display |
3192-01-02.00 |
3192-02-02.00 |
with option 1 analogue output |
3192-01-04.00 |
3192-02-04.00 |
with option2 limit value |
3192-01-06.00 |
3192-02-06.00 |
with option 1 analogue output and 2 limit value |
3192-01-08.00 |
3192-02-08.00 |
230VAC |
only display |
3192-01-01.00 |
3192-02-01.00 |
with option 1 analogue output |
3192-01-03.00 |
3192-02-03.00 |
with option2 limit value |
3192-01-05.00 |
3192-02-05.00 |
with option 1 analogue output and 2 limit value |
3192-01-07.00 |