CAN Pressure sensor technical data |
Overload range |
2 x nominal pressure |
Burst pressure |
3 x nominal pressure |
Signal type |
CANopen, digital |
Supply voltage Ub |
... at 4 ... 20 mA |
12 ... 27 VDC |
... at 0 ... 10 VDC |
- |
Current consumption |
10 ... 30 mA, depends on CAN bus load |
Overvoltage protection |
± 40 VDC |
Error limit (of fi nal value) |
comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error |
... at +22 °C (room temperature) |
±0.5% |
... at -15 ... +85°C |
±0.5% |
... at +85 ... +100°C |
± 1.0 % |
... at -40 ... -15°C |
± 1.0 % |
Compensation temperature range |
-15 ... +85 °C |
Non-linearity |
< ± 0.2 % of final value |
Reproducability |
< ± 0.1 % of final value |
Hysterese |
< ± 0.1 % of final value |
Long-term stability |
< ± 0.1 % of final value/year |
Response time |
< = 1 ms (10 ... 90 %) |
Frequency range |
< = 1 kHz |
Isolation resistance |
min. 100 MOhm |
Total resistance |
RG = (Ub -10 V) / 20 mA (at output signal 4 ... 20 mA) |
Load resistance |
RL = > 5 kOhm (at output signal 0 ... 10 VDC) |
Number of load cycles |
> 1 x 107 |
Medium temperature |
-40 ... +105 °C |
Environmental temperature |
-40 ... +105 °C |
Storage temperature |
-40...+125 |
EMV test |
EN 50081-2 and EN 50082-2 |
Vibrational stability |
IEC 68-2-6 and IEC 68-2-36, 20 g |
Shock stability |
50 g (11 ms half-sine) |
Electrical measuring connector |
5 pole device connector, M12 x 1 |
Mechanical connection thread |
ISO228-G1/4A |
Sealing material |
profi le seal ring acc. to DIN 3869, FKM |
Protection type (EN 60529 / IEC 529) |
IP 67 (with screwed connector) |
Casing material |
non-corrosive high-grade steel |
Membrane material |
non-corrosive high-grade steel |
Tightening torque |
40 Nm (± 5 Nm) |
Weight |
~ 100 g |
CAN bus |
LSS slave function |
Baud rate |
10 ... 500 kBaud (settable) |
CAN interface |
acc. to DIN 11898 |