hydrotechnik

CAN Pressure sensor

Hydrotechnik in china
CAN Pressure sensor data download

CAN Pressure sensor technical data

Overload range 2 x nominal pressure
Burst pressure 3 x nominal pressure
Signal type CANopen, digital
Supply voltage Ub
... at 4 ... 20 mA 12 ... 27 VDC
... at 0 ... 10 VDC -
Current consumption 10 ... 30 mA, depends on CAN bus load
Overvoltage protection ± 40 VDC
Error limit (of fi nal value) comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error
... at +22 °C (room temperature) ±0.5%
... at -15 ... +85°C ±0.5%
... at +85 ... +100°C ± 1.0 %
... at -40 ... -15°C ± 1.0 %
Compensation temperature range -15 ... +85 °C
Non-linearity < ± 0.2 % of final value
Reproducability < ± 0.1 % of final value
Hysterese < ± 0.1 % of final value
Long-term stability < ± 0.1 % of final value/year
Response time < = 1 ms (10 ... 90 %)
Frequency range < = 1 kHz
Isolation resistance min. 100 MOhm
Total resistance RG = (Ub -10 V) / 20 mA (at output signal 4 ... 20 mA)
Load resistance RL = > 5 kOhm (at output signal 0 ... 10 VDC)
Number of load cycles > 1 x 107
Medium temperature -40 ... +105 °C
Environmental temperature -40 ... +105 °C
Storage temperature -40...+125
EMV test EN 50081-2 and EN 50082-2
Vibrational stability IEC 68-2-6 and IEC 68-2-36, 20 g
Shock stability 50 g (11 ms half-sine)
Electrical measuring connector 5 pole device connector, M12 x 1
Mechanical connection thread ISO228-G1/4A
Sealing material profi le seal ring acc. to DIN 3869, FKM
Protection type (EN 60529 / IEC 529) IP 67 (with screwed connector)
Casing material non-corrosive high-grade steel
Membrane material non-corrosive high-grade steel
Tightening torque 40 Nm (± 5 Nm)
Weight ~ 100 g
CAN bus LSS slave function
Baud rate 10 ... 500 kBaud (settable)
CAN interface acc. to DIN 11898

Hydrotechnik CAN Pressure sensor Electrical connector

Pin assignment CANopen
1 CAN_SHLD
2 CAN_V+
3 CAN_GND
4 CAN_H
5 CAN_L
MINIMESS® direct connector for CAN pressure sensors
Execution Pressure sensor Pmax Order number
Direct conn. straight – 1620 CAN 63MPa 2103-07-18.62
Direct connector 90° – 1620 CAN 63MPa 2146-13-05.00
Hydrotechnik CAN pressure sensors
Measuring range(MPa) Measuring range(Bar) CANopen
0 ... 10 0 ... 100 3403-16-D2.60
0 ... 40 0 ... 400 3403-15-D2.60
0 ... 60 0 ... 600 3403-18-D2.60
HT-PD Related products